projects:biosonification

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
projects:biosonification [2026/08/31 01:26] John Harrisonprojects:biosonification [2026/08/31 02:07] (current) John Harrison
Line 77: Line 77:
 The NIME paper's test used a "copper electrode roughly 5cm × 2cm", and a ~15cm rosemary plant with an electrode placed in soil. This is a documented working starting point. The NIME paper's test used a "copper electrode roughly 5cm × 2cm", and a ~15cm rosemary plant with an electrode placed in soil. This is a documented working starting point.
  
-===== Hardware — board compatibility (verified from source) =====+===== Hardware — board compatibility =====
  
   * All Megas work unmodified: Original Mega (ATmega1280), Mega 2560. Mega ADK carries some risk with digital pin 7 so maybe stay away.   * All Megas work unmodified: Original Mega (ATmega1280), Mega 2560. Mega ADK carries some risk with digital pin 7 so maybe stay away.
Line 136: Line 136:
   * Grounding: one project reported needing the person coupled to circuit ground.   * Grounding: one project reported needing the person coupled to circuit ground.
  
-===== Shelved =====+===== Alternative =====
   * **AD5932 sine wave generator:** what Disney used. Cleaner than our circuit but more complicated approach for starting out.   * **AD5932 sine wave generator:** what Disney used. Cleaner than our circuit but more complicated approach for starting out.
     * [[https://pmdway.com/products/ad9833-dds-programmable-frequency-function-generator|this is a good module for testing]]     * [[https://pmdway.com/products/ad9833-dds-programmable-frequency-function-generator|this is a good module for testing]]
 +
 +===== Shelved =====
   * **AD5933 impedance spectroscopy:** two-electrode, measures impedance not self-capacitance. Possible module: KDT5933-013-SOU.   * **AD5933 impedance spectroscopy:** two-electrode, measures impedance not self-capacitance. Possible module: KDT5933-013-SOU.
   * **Biopotential/electrophysiology:** more meaningful for passive environmental sensing, but every long-term result used lab-fabricated electrodes (SWCNT, thermoresponsive polymer, PEDOT:PSS). Off the table without university facilities   * **Biopotential/electrophysiology:** more meaningful for passive environmental sensing, but every long-term result used lab-fabricated electrodes (SWCNT, thermoresponsive polymer, PEDOT:PSS). Off the table without university facilities
  • projects/biosonification.1788139562.txt.gz
  • Last modified: 2026/08/31 01:26
  • by John Harrison